Pirani Gauges

PSG50x & PSG51x

ATM To Medium Vacuum Gauge

Pirani-PSG5XX
Drop-in Options

Revolutionize your vacuum gauge experience with us!

Product configurator

Gemini™ MxG5xx

Type
Sensor version
Ionization chamber
Emmision current
Flange connection to vacuum chamber
Switching function
Electrical connection
Digital interface
Analog output signal
Your configuration
inficon-gauge
Gemini™ MxG5xx
Flange
DN 16 ISO-KF
Switching functions
None
Electrical Connection
FCC, 8-pin
Digital Interface
None
Measurement range
1.2 - 8.68 V
Request
Personal information
Product
inficon-gauge
Gemini™ MxG5xx
Gemini™ MAG500
Your configuration has been successfully sent!

The INFICON Pirani Standard Gauges, PSG500, PSG502-S, PSG510-S and PSG512-S, employ the most advanced digital Pirani technology available in themarketplace. 

The rugged stainless steel sensor cell and compact design qualifythem for use on semiconductor systems and for standard applications, such as fore vacuum lines.

Advantages

  • Easy push button ATM and HV adjustment
  • Space saving rugged design
  • Aluminum housing
  • Mounts in any orientation
  • Stainless steel measuring cell with metal-sealed feedthrough
  • Logarithmic signal output for easy integration
  • 10 bar absolute overpressure with threaded connections
  • 250 °C bakeable version
  • Nickel filament option for corrosive applications
  • Ceramic feedthrough for extremely corrosive applications (PSG510 & PSG512)
  • Optional setpoints
  • RoHS compliance

Typical applications

  • Controlling high vacuum ionization gauges
  • Fore vacuum pressure monitoring
  • Safety circuits in vacuum systems
  • General vacuum measurement and control in the fine and rough vacuum range

Specifications

PSG500 tungsten
PSG500-S tungsten, setpoints
PSG502-S nickel, setpoints
PSG510-S tungsten, setpoints, ceramic feedthroughs
PSG512-S nickel, setpoints, ceramic feedthroughs
Measurement rangeV+1.9 … +10.0
Accuracy(N2)  
1 x 10-3 … 100 mbar% of reading±15%
5 x 10-4 … 1 x 10-3 mbar% of reading±50%
100 … 1000 mbar% of reading±50%
Repeatability (air)  
1 x 10-3 … 100 mbar% of reading2%
Admissible temperature  
Operation°C+5 … +60
Vacuum connection (1)°C80 / 250 (2)
Storage°C-20 … +65
Supply voltage  
At gaugeV (dc)+14 …+30
RippleV (p-p)≤1
Power consumptionW≤1
Setpoint  
Number of setpointsNumber of setpointsnone
Setting rangembar
Hysteresis% of reading
Relay contact 
Relay contact: Switching timems
Materials exposed to vacuum glass, Ni, NiFe, DIN 1.4301 / 1.4305 / 1.4435
Measurement rangeV+1.9 … +10.0
Accuracy(N2)  
1 x 10-3 … 100 mbar% of reading±15%
5 x 10-4 … 1 x 10-3 mbar% of reading±50%
100 … 1000 mbar% of reading±50%
Repeatability (air)  
1 x 10-3 … 100 mbar% of reading2%
Admissible temperature  
Operation°C+5 … +60
Vacuum connection (1)°C80 / 250 (2)
Storage°C-20 … +65
Supply voltage  
At gaugeV (dc)+14 …+30
RippleV (p-p)≤1
Power consumptionW≤1
Setpoint  
Number of setpointsNumber of setpoints2
Setting rangembar2 x 10-3 … 500
Hysteresis% of reading10% above lower threshold
Relay contact 30
Relay contact: Switching timems<20
Materials exposed to vacuum glass, Ni, NiFe, DIN 1.4301 / 1.4305 / 1.4435
Measurement rangeV+1.9 … +10.0
Accuracy(N2)  
1 x 10-3 … 100 mbar% of reading±15%
5 x 10-4 … 1 x 10-3 mbar% of reading±50%
100 … 1000 mbar% of reading±50%
Repeatability (air)  
1 x 10-3 … 100 mbar% of reading2%
Admissible temperature  
Operation°C+5 … +60
Vacuum connection (1)°C80 / 250 (2)
Storage°C-20 … +65
Supply voltage  
At gaugeV (dc)+14 …+30
RippleV (p-p)≤1
Power consumptionW≤1
Setpoint  
Number of setpointsNumber of setpoints2
Setting rangembar2 x 10-3 … 500
Hysteresis% of reading10% above lower threshold
Relay contact 30
Relay contact: Switching timems<20
Materials exposed to vacuum glass, Ni, NiFe, DIN 1.4301 / 1.4305 / 1.4435
Measurement rangeV+1.9 … +10.0
Accuracy(N2)  
1 x 10-3 … 100 mbar% of reading±15%
5 x 10-4 … 1 x 10-3 mbar% of reading±50%
100 … 1000 mbar% of reading±50%
Repeatability (air)  
1 x 10-3 … 100 mbar% of reading2%
Admissible temperature  
Operation°C+5 … +60
Vacuum connection (1)°C80 / 250 (2)
Storage°C-20 … +65
Supply voltage  
At gaugeV (dc)+14 …+30
RippleV (p-p)≤1
Power consumptionW≤1
Setpoint  
Number of setpointsNumber of setpoints2
Setting rangembar2 x 10-3 … 500
Hysteresis% of reading10% above lower threshold
Relay contact 30
Relay contact: Switching timems<20
Materials exposed to vacuum AI2O3, Ni, DIN 1.3981 / 1.4305 / 1.4435
Measurement rangeV+1.9 … +10.0
Accuracy(N2)  
1 x 10-3 … 100 mbar% of reading±15%
5 x 10-4 … 1 x 10-3 mbar% of reading±50%
100 … 1000 mbar% of reading±50%
Repeatability (air)  
1 x 10-3 … 100 mbar% of reading2%
Admissible temperature  
Operation°C+5 … +60
Vacuum connection (1)°C80 / 250 (2)
Storage°C-20 … +65
Supply voltage  
At gaugeV (dc)+14 …+30
RippleV (p-p)≤1
Power consumptionW≤1
Setpoint  
Number of setpointsNumber of setpoints2
Setting rangembar2 x 10-3 … 500
Hysteresis% of reading10% above lower threshold
Relay contact 30
Relay contact: Switching timems<20
Materials exposed to vacuum AI2O3, Ni, DIN 1.3981 / 1.4305 / 1.4435
Download full specifications

Part Number

Part Number
Accessories
Spare Parts
PSG500 tungsten 
350-060PSG500 DN 16 ISO-KF.
350-061PSG500 1/8" NPT
350-062PSG500 DN 16 CF-R
350-063PSG500 1/2" Tube
350-064PSG500 8-VCR (1/2")
350-065PSG500 4-VCR (1/4")
350-066PSG500 7/16-20 UNF
350-067PSG500 DN 16 ISO-KF, ext. body
350-068PSG500 DN 16 CF-R, ext. body
  
PSG500-S tungsten, setpoints 
350-080PSG500-S DN 16 ISO-KF
350-081PSG500-S 1/8" NPT
350-082PSG500-S DN 16 CF-R
350-083PSG500-S 1/2" Tube
350-084PSG500-S 8-VCR (1/2")
350-085PSG500-S 4-VCR (1/4")
350-086PSG500-S 7/16-20 UNF
350-087PSG500-S DN 16 ISO-KF, ext. body
350-088PSG500-S DN 16 CF-R, ext. body
  
PSG502-S nickel, setpoints 
350-140PSG502-S DN 16 ISO-KF
350-141PSG502-S 1/8" NPT
350-142PSG502-S DN 16 CF-R
350-143PSG502-S 1/2" Tube
350-144PSG502-S 8-VCR (1/2")
350-145PSG502-S 4-VCR (1/4")
350-146PSG502-S 7/16-20 UNF
350-147PSG502-S DN 16 ISO-KF, ext. body
350-148PSG502-S DN 16 CF-R, ext. body
  
PSG510-S tungsten, setpoints, ceramic feedthroughs 
350-200PSG510-S DN 16 ISO-KF
  
PSG512-S nickel, setpoints, ceramic feedthroughs 
350-300PSG512-S DN 16 ISO-KF
PSG500 tungsten 
211-001Clamping ring DN 10-16 ISO-KF
350-050Power Supply, PxG5xx,G-Cable FCC,1.8m
  
PSG500-S tungsten, setpoints 
211-001Clamping ring DN 10-16 ISO-KF
350-050Power Supply, PxG5xx,G-Cable FCC,1.8m
  
PSG502-S nickel, setpoints 
211-001Clamping ring DN 10-16 ISO-KF
350-050Power Supply, PxG5xx,G-Cable FCC,1.8m
  
PSG510-S tungsten, setpoints, ceramic feedthroughs 
211-001Clamping ring DN 10-16 ISO-KF
350-050Power Supply, PxG5xx,G-Cable FCC,1.8m
  
PSG512-S nickel, setpoints, ceramic feedthroughs 
211-001Clamping ring DN 10-16 ISO-KF
350-050Power Supply, PxG5xx,G-Cable FCC,1.8m
PSG500 tungsten 
350-920PSG500 Spare Sensor DN 16 KF
350-921PSG500 Spare Sensor 1/8" NPT
350-922PSG500 Spare Sensor DN 16 CF-R
350-923PSG500 Spare Sensor 1/2" Tube
350-924PSG500 Spare Sensor 8-VCR (1/2")
350-925PSG500 Spare Sensor 7/16-20 UNF
350-926PSG500 Spare Sensor 4-VCR (1/4")
350-927PSG500 Spare Sensor DN 16 KF,ext.body
350-928PSG500 Spare Sensor DN 16 CF-R,ext.body
  
PSG500-S tungsten, setpoints 
350-920PSG500 Spare Sensor DN 16 KF
350-921PSG500 Spare Sensor 1/8" NPT
350-922PSG500 Spare Sensor DN 16 CF-R
350-923PSG500 Spare Sensor 1/2" Tube
350-924PSG500 Spare Sensor 8-VCR (1/2")
350-925PSG500 Spare Sensor 7/16-20 UNF
350-926PSG500 Spare Sensor 4-VCR (1/4")
350-927PSG500 Spare Sensor DN 16 KF,ext.body
350-928PSG500 Spare Sensor DN 16 CF-R,ext.body
  
PSG502-S nickel, setpoints 
350-900PSG502 Spare Sensor DN 16 KF
350-901PSG502 Spare Sensor 1/8" NPT
350-902PSG502 Spare Sensor DN 16 CF-R
350-903PSG502 Spare Sensor 1/2" Tube
350-904PSG502 Spare Sensor 8-VCR (1/2")
350-905PSG502 Spare Sensor 7/16-20 UNF
350-906PSG502 Spare Sensor 4-VCR (1/4")
350-907PSG502 Spare Sensor DN 16 KF,ext.body
350-908PSG502 Spare Sensor DN 16 CF-R,ext.body
  
PSG510-S tungsten, setpoints, ceramic feedthroughs 
350-930PSG510 Spare Sensor DN 16 KF
  
PSG512-S nickel, setpoints, ceramic feedthroughs 
350-940PSG512 Spare Sensor DN 16 KF

Downloads

3D Step Files
The product is used in the following markets
Analytical-Instrumentation-Navi
Analytical Instrumentation

Supports with their highly sophisticated tools users in a broad filed of applications and markets. 

Learn more
Battery-Market-Navi
Battery

From electrode production to end-of-line testing

Learn more
Display-Navi
Display

INFICON supports leading-edge technology and enables the highest quality Display products

Learn more
energy-market-navi
Energy

Oil and gas production has seen an increase in demand over the last decades and is being propelled by population growth, urbanization, and the consumer middle class in developing countries.

Learn more
HVACR-Navi
HVAC/R

Refrigeration and air conditioning technology is undoubtedly one of the important topics of the 21st century. Effectiveness of use, energy efficiency, and last but not least optimal temperatures or an optimal climate (in the private as well as commercial sector) play an important role. 

Learn more
Industrial-Manufacturing-Navi-2
Industrial Manufacturing

Vacuum is used more often to guarantee clean environment and is needed for several processes, then without vacuum they do not work.

Learn more
Mobility_and_Automotive-Navi
Mobility & Automotive

Reliable leak testing in an evolving industry. Changes in the automotive industry make leak testing even more important.

Learn more
Pharma_and_Medical-Navi
Pharma & Medical

Increasing Productivity and helping meet Compliance standards and Quality requirements in Pharma 

Learn more
Research-and-Academia-Navi
Research & Academia

Unveiling the innermost mysteries of the universe through fundamental research. Delivering the innovation today that empowers the technologies of your tomorrow.

Learn more
Semiconductur-IDM-and-Foundry-Navi
Semiconductor IDM & Foundry

Sensors tailored to support a wide range of applications, ensuring product safety, increased yield and maximum productivity

Learn more
Vacuum_Coating-Navi
Vacuum Coating

The vacuum coating markets go well beyond optics and are rapidly expanding into arenas, industries and film layers that were almost unimaginable just ten years ago.

Learn more
We require your consent for video content
More Information