INFICON 뉴스

제품 및 서비스에 대해 자세히 알아보기

Webinar Crystals
웨비나

Temperature Compensation for QCMs

위치
Online
언어
English
발표자
Sheldon Wayman
소요 시간
20 minutes

About the webinar

Quartz crystal microbalance (QCM) technology has been used for decades to control deposition rate and thickness for the most complex processes seen in the ophthalmic, optical, display, and solar markets. INFICON has recently made a new advancement in QCM technology to address a problem seen across all of these industries related to QCM temperature effects. Thermal shock can cause QCM thickness errors which can decrease yield and increase manufacturing costs if temperature is not accounted for correctly.

Temperature impacts the frequency measurement and can create false mass readings. Thin film deposition controllers currently on the market have no good way of distinguishing frequency shifts related to mass from frequency shifts related to temperature, resulting in thickness errors and poor PID control. This can be detrimental to complex coating processes due to the low deposition rates and incredibly thin layers required. Thermal shocks can occur at any point in a deposition process and can cause unnecessary PID-loop corrections, triggering non-uniform deposition in respect to time. This means that the quality throughout the bulk of the material is inadequate. For very thin films, the thickness termination may not be at the real intended thickness because the process time window is small compared to the time allowed for a QCM to recover from a thermal shock event.

INFICON has patented a new temperature compensation technique for SC-cut crystals to remove the effects of temperature variation on the QCM without the need for additional hardware or custom and expensive sensors.

Please watch this ‘Temperature Compensation for QCMs’ webinar, hosted by Sheldon Wayman, Product Engineer for INFICON Inc.

Related information

product
Quartz Monitor Crystals

크리스탈의 품질과 수명은 속도와 두께 측정의 정확성뿐만 아니라 제어되는 공정의 성공적인 완료에도 중요한 영향을 미칩니다

추가 정보
product
1 인치(25.4 MM) 연구용 크리스탈

INFICON이 개척한 표준 AT판, 1인치(25.4 mm) 직경의 크리스탈은 INFICON RQCM(연구용 석영 크리스탈 마이크로밸런스)과 함께 연구 분야에서 주로 사용됩니다

추가 정보
product
IMM-100

Compact deposition monitor built with ModeLock technology to maximize reproducibility and uniformity with the highest thickness accuracy, best measurement resolution, and lowest rate noise

추가 정보
product
IMM-200

Compact deposition monitor built with ModeLock technology to maximize reproducibility and uniformity with the highest thickness accuracy, best measurement resolution, and lowest rate noise

추가 정보
product
SemiQCM™ SR Sensors for Precursor Monitoring

SemiQCM™ SR sensor is one component of a system for precursor monitoring with the other components being an IMM-200 and FabGuard (version 19.12.00-a or higher).

추가 정보
product
SemiQCM™ CR Sensors For Precursor Monitoring

real-Time, in situ process monitoring, prevent over-etching, identify chamber clean end point

추가 정보
news
4월, 마그네슘 감응형 OLED 크리스탈 사용의 이점을 발견하다

안정성 향상, 두께 정확도 개선 및 시간 절약

추가 정보
비디오 콘텐츠에 대한 동의가 필요합니다
자세한 정보